Abstract
This thesis develops and evaluates a mixed-reality system combining finger-specificvibrotactile stimulation, embodied passthrough interaction, audiovisual overlays,
response recording, and hand-movement exercises. Implemented in Unity for the Meta
Quest 3, the application uses markerless hand tracking to position virtual stimuli at the
user’s fingertips. A wireless ESP32-based control unit operates three fingertip-mounted
eccentric rotating mass motors through addressable DRV2605L haptic drivers. Digital
drive levels, motor identifiers, pulse events, timestamps, and button responses were
recorded. Hand-movement recording and playback provide a basis for guided motor
exercises and tele-rehabilitation.
The experimental study investigated whether the estimated transition between per
ceived and non-perceived vibrotactile stimulation differed across three multisensory con
ditions. Seven participants completed a tactile-only baseline condition with closed eyes,
an anticipatory visual condition involving a virtual ball approaching the fingertip, and
a non-anticipatory audiovisual condition using an abrupt lightning effect and auditory
cue. Vibrotactile pulses had a fixed duration of 100 ms, while the vibration intensity
amplitude, also referred to as digital drive level, varied around a participant-specific
near-threshold value. Responses were first evaluated separately for each finger and then
combined within participants. The primary outcome was an estimated transition mid
point derived from the response-linked and non-response-linked drive-level distributions.
The group mean transition midpoint decreased from 33.29 in the tactile-only condi
tion to 30.98 in the anticipatory condition and increased to 32.17 in the non-anticipatory
condition. The largest observed change was the mean decrease of 2.30 between the base
line and anticipatory conditions, occurring in five of the seven participants. The non
anticipatory condition remained below baseline for six participants but was higher than
the anticipatory condition for five participants. This indicates a descriptive tendency
toward lower transition midpoints under multisensory stimulation, with the strongest
decrease occurring in the anticipatory condition. However, the small sample did not
provide sufficient statistical evidence to confirm these differences. The null hypothesis
could therefore not be rejected, which does not demonstrate the absence of an effect
but limits generalization beyond the present sample.
The system achieved a mean System Usability Scale score of 78.93, while the custom
questionnaire showed generally favorable responses and strong interest in a purpose
optimized application. Overall, the work establishes a functional framework for com
bining multisensory stimulation, vibrotactile assessment, embodied mixed-reality inter
action, and motor-exercise guidance, while providing directions for a larger and more
controlled follow-up study.