Skip to main navigation Skip to search Skip to main content

Fitting Parametric Human Body Models to Anthropometric Measurements

  • Maja Katharina Nikolic

    Student thesis: Master's Thesis

    Abstract

    Accurate parametric 3D human body models are relevant for several applications, in
    cluding medical use cases such as burn care, where patient-specific body models can
    support the estimation of the percentage of burned body surface area which is a key
    metric for burn assessment and treatment planning. Generating these models from sim
    ple anthropometric measurements provides a cheaper and more practical alternative to
    3D body scanners and image-based reconstruction methods, especially for patients with
    limited mobility. However, anthropometric measurements are affected by measurement
    uncertainty and differ systematically from measurements derived from parametric body
    models. These inconsistencies can bias the reconstruction process and may result in
    body shapes that match the input measurements but are anatomically implausible.
    This thesis investigates the reconstruction of SMPL body shapes from anthropo
    metric measurements, with a focus on estimating accurate and anatomically plausible
    SMPL shape parameters from measurements obtained under real-world measurement
    conditions. For this purpose, multiple SMPL-based and anthropometric datasets with
    different acquisition modalities are used, including manually measured, scan-derived,
    and SMPL-derived measurements. A dataset containing manual tape measurements and
    corresponding fitted SMPL body models for the same subjects is used for mesh-level
    evaluation.
    Several regression models and a per-sample optimization method are investigated. In
    addition to standard regression models, a custom loss function is introduced to optimize
    the reconstructed anthropometric measurements while regularizing the estimated SMPL
    shape parameters. Among the evaluated approaches, the per-sample optimizer offers the
    greatest practical flexibility, as it can use any available subset of measurements and does
    not require missing measurements to be explicitly imputed.
    The results show that 3D body models can be reconstructed from a limited set of
    anthropometric measurements with reasonable accuracy. In the final evaluation, the
    per-sample optimizer achieves a mean per-vertex error of 12–17 mm. The generated
    models show reasonable global shape accuracy, although larger local deviations remain
    in regions that are not sufficiently constrained by the available measurements. Overall,
    this thesis demonstrates that anthropometric measurements can serve as a promising
    input modality for generating patient-specific 3D body models, while showing that mea
    surement uncertainty and modality-dependent differences must be carefully considered.
    Date of Award2026
    Original languageEnglish (American)
    Awarding Institution
    • FH OÖ
    SupervisorUlrich Bodenhofer (Supervisor)

    Studyprogram

    • Data Science and Engineering

    Cite this

    '