    Abstract

    Classical machine guarding is static. A fence or a fixed safety zone must enclose the
    machine’s entire range of motion. A zone that follows the hazard can release unused
    workspace. It requires the safety sensor to locate the hazard in every frame on its own
    hardware.
    This thesis develops and evaluates a marker-tracking pipeline for the safety-certified
    SpotGuard Time-of-Flight (ToF) camera. The hazard carries a passive sphere of known
    size. Four baseline detection methods share one interface, from geometric model fitting
    to a small convolutional network. A Kalman filter supplies the smoothed position, look
    ahead prediction, and track-loss state required by a dynamic zone.
    Evaluation uses simulation with exact ground truth, recorded camera frames, and
    timing on the camera’s i.MX6 processor. RANSAC is the fastest and most accurate
    baseline in the three clean simulation presets, with about 1mm mean position error.
    RANSAC, fusion, and ML keep mean 300ms look-ahead errors below 50mm on clean
    data. Under combined disturbances at near range, extrapolation is worse than holding
    the last position. All six optimized timing configurations meet the 50ms mean compute
    budget in the tested runs. Five sustain the camera’s frame rate without drops in the
    empty-scene live test, including frame ingestion and output.
    On real recordings, surface depth noise limits sphere fitting to about 2m. Two further
    detector configurations use depth segmentation and adaptive gating. Together with
    temporal depth averaging, they extend detection on the recorded distance ladder to
    at least 3.17m. With temporal confirmation, track availability reaches 69–97% on five
    dynamic sequences and 36% on fast motion. This availability includes coasting and false
    tracks. It does not measure correct-detection recall.
    The delivered system runs standalone on the device. It reads memory-mapped frames
    and publishes track and zone records over TCP/IP. Certified zone integration, an IR
    opaque marker coating, and broader real training data remain future work.