Skip to main navigation Skip to search Skip to main content

A Light-Sheet Imaging Pipeline and Software for Spray Brush Measurement in Robotic Automotive Coating

  • Julian Lenzenweger

    Student thesis: Master's Thesis

    Abstract

    Robotic top-coat application in automotive manufacturing is set up in physical trials,
    in which a car body is coated, cured, and inspected until the deposited film meets the
    quality requirements. Simulating the deposition on a virtual car body replaces part of
    these trials, but resolving the atomization process is not feasible at scale. A simplified
    prediction instead projects measured cross-profiles of individual sprays onto the body,
    which requires a large profile library. With the conventional measurement, the manual
    effort grows with every profile added to that library.
    This thesis presents a low-cost laser-sheet imaging pipeline that captures the shape
    of a spray brush at a defined standoff distance in a painting facility. A laser sheet
    illuminates a thin cross-section of the spray, and a consumer action camera records
    the scattered light over a few seconds. A graphical application, operable without
    programming knowledge, converts the frames to intensity, filters them, and reduces the
    recording to the per-pixel mean and a fluctuation metric. The fluctuation separates the
    stable core from the surrounding overspray. The intensity is then scaled to an absolute
    film thickness.
    The method is evaluated against conventional plate measurements for a Rotary Bell
    Atomizer with a black paint and a clearcoat. The recorded profiles reproduce the shape
    of the reference for every compared brush, while width and absolute peak thickness
    agree less closely. The deviation accumulates over the conversion chain, in particular
    over the scaling to an absolute thickness, which relies on an assumed transfer efficiency
    and on the geometry of the reference pass. The recording depends on a darkened,
    spatially calibrated environment whose preparation is required once per session rather
    than once per brush. The method therefore lowers the effort per brush and suits the
    construction of the profile library, while the conventional measurement remains the
    reference where a certified value is required.
    Date of Award2026
    Original languageEnglish (American)
    Awarding Institution
    • FH OÖ
    SupervisorHans-Georg Brachtendorf (Supervisor)

    Studyprogram

    • Embedded Systems Design

    Cite this

    '