Temperature-Controlled in-situ Tensile Tests of Polymer Tape with Single Particles

Research output: Contribution to journalArticlepeer-review

Abstract

X-ray Computed Tomography (CT) combined with mechanical testing can deliver great insights in the damage mechanisms of polymers. Depending on the application area of the polymer, temperatures can be very high or low – leading to a different performance compared to room temperature. In this study, the influence of the temperature on damage mechanisms of a single particle in a polymer matrix should be investigated. Thus, three polymer tensile test specimens (length 30 mm; width 10 mm) – each containing a single particle – were cut out of a tape with a thickness of 0.5 mm and tested at various inspection temperatures. CT measurements were performed with the RX Solutions Easytom 160 laboratory CT device with a voxel size of (3 µm)³. Each specimen was scanned twice, namely at 0% strain and 30% strain. As inspection temperatures 0 °C, 22 °C and 60 °C were chosen. It is shown that temperature can have a great impact on the performance and damage mechanisms of a polymer, especially if a particle is present in the polymer matrix.
Original languageEnglish
JournalResearch and Review Journal of Nondestructive Testing
Volume1
Issue number1
DOIs
Publication statusPublished - Aug 2023