On the advantages of economically designed the Hotelling’s T2 control chart with variable sample sizes and sampling intervals

Alireza Faraz

Research output: Contribution to journalArticlepeer-review

10 Citations (Scopus)

Abstract

Faraz and Parsian (Statistical Paper, 47: 569-593, 2006) have shown that the double warning lines (DWL) scheme detects process shifts more quickly than the other variable ratio sampling schemes such as variable sample sizes (VSS), variable sampling intervals (VSI) and variable sample sizes and sampling intervals (VSSVSI). In this paper, the DWLT2control chart for monitoring the process mean vector is economically designed. The cost model proposed by Costa and Rahim (Journal of Applied Statistics, 28: 875-885, 2001) is used here and is minimized through a genetic algorithm (GA) approach. Then the effects of the model parameters on the chart parameters and resulting operating loss is studied and finally a comparison between all possible variable ratio sampling (VRS) schemes are made to choose the best option economically.

Original languageEnglish
Pages (from-to)39-53
Number of pages15
JournalQUALITY & QUANTITY
Volume46
Issue number1
DOIs
Publication statusPublished - Jan 2012

Keywords

  • Adjusted average time to signal (AATS)
  • Economic design
  • Genetic algorithm (GA)
  • Hotelling's T control chart
  • Markov chain
  • Variable sample size and sampling interval (VSSVSI) scheme