Abstract
In this work we present the potential of Scanning Acoustic Microscopy (SAM) as an important non-destructive evaluation (NDE) method for process control as well as failure analysis of thermoelectric modules (TE-modules). SAM is one part of the so called ‘Dream Team Concept’ which is described in detail in section 2.
| Original language | English |
|---|---|
| Pages (from-to) | 26-33 |
| Number of pages | 8 |
| Journal | Journal of Thermoelectricity |
| Volume | 2024 |
| Issue number | 4 |
| DOIs | |
| Publication status | Published - 25 Dec 2024 |
Keywords
- non-destructive inspection
- scanning acoustic microscopy
- thermoelectric modules