Abstract
The purpose of the first part of this study was to compare four different temperature measuring methods. The application of these tools for possible temperature monitoring or calibration of monitors of microtubular solid oxide fuel cells (MT-SOFCs) is explored. It was found that a thermographic camera is very useful to visualize the temperature gradient on the outside of a cell, while an electrochemical impedance spectroscopy method was useful for estimating the core temperature of a test cell. A standard thermocouple was also used in combination with the previous two methods. Furthermore, an inexpensive laser guided thermometer was also tested for MT-SOFC temperature measurement. This initial study has opened up a range of questions not only about the effect of the experimental apparatus on the measurement results but also about the radial temperature distribution through a MT-SOFC in a working mode. Both these topics will be further investigated in part II of this study through a computational fluid dynamics study. This should provide additional interesting information about any differences between testing single cells and those within a bundle of cells. The discussed results are expected to be mainly temperature related, which should have direct consequences on power output and optimized gas inlet temperatures.
Originalsprache | Englisch |
---|---|
Aufsatznummer | 061016 |
Seiten (von - bis) | 1016-1023 |
Fachzeitschrift | Journal of Fuel Cell Science and Technology |
Jahrgang | 7 |
Ausgabenummer | 6 |
DOIs | |
Publikationsstatus | Veröffentlicht - Dez. 2010 |