Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography

Patricia Brunner, Robert Merwa, Andreas Missner, Javier Rosell, Karl Hollaus, Hermann Scharfetter

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

40 Zitate (Scopus)

Abstract

Magnetic induction tomography (MIT) of biological tissue is used for the reconstruction of the complex conductivity distribution κ inside the object under investigation. It is based on the perturbation of an alternating magnetic field caused by the object and can be used in all applications of electrical impedance tomography (EIT) such as functional lung monitoring and assessment of tissue fluids. In contrast to EIT, MIT does not require electrodes and magnetic fields can also penetrate non-conducting barriers such as the skull. As in EIT, the reconstruction of absolute conductivity values is very difficult because of the method's sensitivity to numerical errors and noise. To overcome this problem, image reconstruction in EIT is often done differentially. Analogously, this concept has been adopted for MIT. Two different methods for differential imaging are applicable. The first one is state-differential, for example when the conductivity change between inspiration and expiration in the lung regions is being detected. The second one is frequency-differential, which is of high interest in motionless organs like the brain, where a state-differential method cannot be applied. An equation for frequency-differential MIT was derived taking into consideration the frequency dependence of the sensitivity matrix. This formula is valid if we can assume that only small conductivity changes occur. In this way, the non-linear inverse problem of MIT can be approximated by a linear one (depending only on the frequency), similar to in EIT. Keeping this limitation in mind, the conductivity changes between one or more reference frequencies and several measurement frequencies were reconstructed, yielding normalized conductivity spectra. Due to the differential character of the method, these spectra do not provide absolute conductivities but preserve the shape of the spectrum. The validity of the method was tested with artificial data generated with a spherical perturbation within a conducting cylinder as well as for real measurement data. The measurement data were obtained from a potato immersed in saline. The resulting spectra were compared with reference measurements and the preservation of the shape of the spectra was analyzed.

OriginalspracheEnglisch
AufsatznummerS20
Seiten (von - bis)237-248
FachzeitschriftPhysiological Measurement
Jahrgang27
Ausgabenummer5
DOIs
PublikationsstatusVeröffentlicht - 1 Mai 2006

Fingerprint

Untersuchen Sie die Forschungsthemen von „Reconstruction of the shape of conductivity spectra using differential multi-frequency magnetic induction tomography“. Zusammen bilden sie einen einzigartigen Fingerprint.

Zitieren