Abstract
Continuous sensor systems are increasingly used to support nursing care, yet the evaluation of their actual benefit depends on reliable ground-truth data collected during routine care conditions. This paper reports lessons learned from a three-center field study investigating multimodal bed monitoring in care facilities. As an example, we evaluate the validation of presence detection using smart incontinence pads against manually documented questionnaires.
The study included 21 participants and generated more than 312 000 sensor messages, 3.6 million analog measurements, and 1504 questionnaire entries. Questionnaire entries were matched with sensor measurements using temporal windows from ±1 to ±30 minutes to assess questionnaire completeness, temporal alignment, and their impact on validation metrics.
While questionnaire coverage reached 94% within a ±5 min matching window, sensor coverage remained low due to the large imbalance between continuously sampled sensor data and manually documented observations. Furthermore, questionnaire completeness varied considerably between study centers, highlighting the influence of local documentation practices on ground-truth quality.
Our findings demonstrate that manually collected questionnaires provide valuable contextual information but are insufficient as the sole reference for validating continuously sampled sensor systems. Future studies should therefore employ synchronized digital documentation integrated into routine care to improve the quality and comparability of groundtruth collection.
The study included 21 participants and generated more than 312 000 sensor messages, 3.6 million analog measurements, and 1504 questionnaire entries. Questionnaire entries were matched with sensor measurements using temporal windows from ±1 to ±30 minutes to assess questionnaire completeness, temporal alignment, and their impact on validation metrics.
While questionnaire coverage reached 94% within a ±5 min matching window, sensor coverage remained low due to the large imbalance between continuously sampled sensor data and manually documented observations. Furthermore, questionnaire completeness varied considerably between study centers, highlighting the influence of local documentation practices on ground-truth quality.
Our findings demonstrate that manually collected questionnaires provide valuable contextual information but are insufficient as the sole reference for validating continuously sampled sensor systems. Future studies should therefore employ synchronized digital documentation integrated into routine care to improve the quality and comparability of groundtruth collection.
| Originalsprache | Englisch |
|---|---|
| Publikationsstatus | Angenommen/Im Druck - 2026 |
| Veranstaltung | 20th EAI International Conference on Pervasive Computing Technologies for Healthcare - Beijing, China Dauer: 15 Okt. 2026 → 17 Okt. 2026 https://pervasivehealth.eai-conferences.org/2026/ |
Konferenz
| Konferenz | 20th EAI International Conference on Pervasive Computing Technologies for Healthcare |
|---|---|
| Kurztitel | EAI PervasiveHealth 2026 |
| Land/Gebiet | China |
| Ort | Beijing |
| Zeitraum | 15.10.2026 → 17.10.2026 |
| Internetadresse |
UN SDGs
Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung
-
SDG 3 – Gute Gesundheit und Wohlergehen
Fingerprint
Untersuchen Sie die Forschungsthemen von „Lessons Learned from Ground-Truth Collection for Multimodal Bed Monitoring“. Zusammen bilden sie einen einzigartigen Fingerprint.Zitieren
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver