TY - JOUR
T1 - Application of abrupt change detection in power systems disturbance analysis and relay performance monitoring
AU - Ukil, Abhisek
AU - Živanović, Rastko
PY - 2007/1
Y1 - 2007/1
N2 - This paper describes the application of the abrupt change detection technologies to detect the abrupt changes in the signals recorded during disturbances in the electrical power network of South Africa for disturbance analysis and relay performance monitoring. The aim is to estimate the time instants of the changes in the signal model parameters during the prefault condition, after initiation of fault, after the circuit-breaker opening and autoreclosure, etc. After these event-specific segmentations, the synchronization of the different digital fault recorder recordings are done based on the fault inception timings. The synchronized signals are segmented again. This synchronized segmentation is the first step toward automatic disturbance recognition, facilitating further complex feature vector analysis and pattern recognition. Besides, the synchronized, segmented recordings can be directly used to analyze certain kinds of disturbances and monitor the relay performance. This paper presents many practical examples from the power network in South Africa.
AB - This paper describes the application of the abrupt change detection technologies to detect the abrupt changes in the signals recorded during disturbances in the electrical power network of South Africa for disturbance analysis and relay performance monitoring. The aim is to estimate the time instants of the changes in the signal model parameters during the prefault condition, after initiation of fault, after the circuit-breaker opening and autoreclosure, etc. After these event-specific segmentations, the synchronization of the different digital fault recorder recordings are done based on the fault inception timings. The synchronized signals are segmented again. This synchronized segmentation is the first step toward automatic disturbance recognition, facilitating further complex feature vector analysis and pattern recognition. Besides, the synchronized, segmented recordings can be directly used to analyze certain kinds of disturbances and monitor the relay performance. This paper presents many practical examples from the power network in South Africa.
KW - Abrupt change detection
KW - Disturbance analysis
KW - Relay performance
KW - Wavelet transform (WT)
UR - http://www.scopus.com/inward/record.url?scp=34147161712&partnerID=8YFLogxK
U2 - 10.1109/TPWRD.2006.887096
DO - 10.1109/TPWRD.2006.887096
M3 - Article
AN - SCOPUS:34147161712
SN - 0885-8977
VL - 22
SP - 59
EP - 66
JO - IEEE Transactions on Power Delivery
JF - IEEE Transactions on Power Delivery
IS - 1
ER -